Single Channel Detector
FX-1500 Single Channel Detector
• Remote electronics/ display
• Sensor can be located as far as 2000 feet from the display unit
• 3 Alarm Levels: Caution, Warning and Danger
• Configurable auxiliary output relays
• L.E.D. display of gas concentration in part per million
• 120 dB Piezo alarm horn
• Relay outputs for all alarm and sensor failure levels
• Local alarm indication and test button at the sensor
• Several types of toxic gas sensors available
• Optional 4-20 milliamp retransmission output available
FX-1500 Toxic Gas Monitor The Foxcroft FX-1500 series of toxic gas leak detectors are perfect for monitoring a gas container storage, generation, or use area. The remote display unit can be located in a control room or save area, outside or away from, the potential gas leak. Warning and Danger alarm levels are set to specific points for the gas being monitored. A third low level alarm (typically 0.5 ppm for most gases), is incorporated in the unit to alert personnel of slow leaks before they become a major problem. A fourth "cell failure" alarm level indicates if there is a problem with the sensor, or wiring to the sensor. All alarm levels are available for connection to external equipment via configurable relay contact outputs. External equipment can be anything that is activated by a dray relay contact, such as; alarm beacons, horns, auto-dialers, fans, or emergency shutoff valves. An optional 4-20 milliamp retransmission output available for connection to SCADA or PLC system, or chart recorder. Special alarm levels and ranges are available on written request. An optional battery backup/ surge protector is also available for applications where AC power is unreliable, or must be maintained in the event of a power failure.
FX-2 Single Channel Detector
FX-2 Single Channel Toxic Gas Detector

The FX-2 deTEC is a feature-packed, industrial-grade, toxic gas leak detector. The high visibility design of the detector makes it easy to see in a room full of equipment, or an industrial environment. It is as affordable expandable device that is designed for long life under today's heavy industrial requirements, and is compact enough to take minimal wall space. The FX-2 can be configured as a single channel or a dual channel gas leak detector.
FX-2 Single Channel Detector • Single Channel
• Programmable Relays
• With or Without Digital Displays
• Easy to Read Control Panel
• High Intensity Visual - Audible Alarms
• Optional 24VDC Power for Remote Locations
• 4-20mA Output (optional)
• SCADA System Ready
• Electronics are Field Upgradable
• One Touch Reset - Silence System
• Solid PVC Construction
• Wall Mount or DIN Rail Mount
• Heavy Duty Clear Acrylic Cover
• Enclosure Solid O-ring Sealed
• Easy to Reach Calibration Points
• High Density All PVC Enclosure
• Single Sensor Package
• Sealed Local Test Button
Ready Single Channel Detector
• Remote electronics/ display
• Sensor can be located as far as 2000 feet from the display unit
• 3 Alarm Levels: Caution, Warning and Danger
• Configurable auxiliary output relays
• L.E.D. display of gas concentration in part per million
• 120 dB Piezo alarm horn
• Relay outputs for all alarm and sensor failure levels
• Local alarm indication and test button at the sensor
• Ready Advanced Sensor ready
• Optional 4-20 milliamp retransmission output available
  The Ready 1 Single Channel toxic gas leak detector is perfect for monitoring a gas container storage, generation, or use area. The remote display unit can be located in a control room or save area, outside or away from, the potential gas leak. Warning and Danger alarm levels are set to specific points for the gas being monitored. A third low level alarm (typically 0.5 ppm for most gases), is incorporated in the unit to alert personnel of slow leaks before they become a major problem. A fourth "cell failure" alarm level indicates if there is a problem with the sensor, or wiring to the sensor. All alarm levels are available for connection to external equipment via configurable relay contact outputs. External equipment can be anything that is activated by a dray relay contact, such as; alarm beacons, horns, auto-dialers, fans, or emergency shutoff valves. An optional 4-20 milliamp retransmission output available for connection to SCADA or PLC system, or chart recorder. Special alarm levels and ranges are available on written request. An optional battery backup/ surge protector is also available for applications where AC power is unreliable, or must be maintained in the event of a power failure. The Ready 1 Single Channel toxic gas leak detector can be adapted to our Ready Advanced Sensors with more advanced technology.
Ready Advanced Toxic Gas Sensors
• Power "On" green LED
• Danger Alarm red blinking LED
• Press button calibration (zero and span)
• Used with all Foxcroft Toxic Leak Detectors (except FX-1 mini)
• Many Toxic gas sensor available
Ready Advanced Toxic Gas Sensor Ready Advanced Toxic Gas Sensors

The Ready Advanced Toxic Gas Sensors have been designed to ensure a maximum reliablility in the field at minimum cost. Small and compact the Ready Advanced Toxic Gas Sensor provides visual "powered" LED as well as a local "Danger" alarm LED. Also, provided is a local electronic test button.
Toxic Gas Sensors
Foxcorft
Single Channel Gas Detectors
Foxcroft Equipment and Service Company, Incorporated
2101 Creek Road - Glenmoore, PA 19343 - USA
1.800.874.0590 - 1.610.942.2888 - FAX 1.610.942.2769
Email: sales@foxcroft.com

All Rights Reserved - All material contained in this Web Site is copyrighted - No material or ideas contained within this Web Site shall be used or copied without written consent from Foxcroft.
©2009 RWI3rd