Sample Point Guidelines
Recommended way's to plumb your FX-1000p Chlorine Analyzer  
Plumbing your FX-1000p Sampling point is dependent on the unique conditions of each installation. Consider these factors when deciding where to locate the sampling point:

• It is desirable to have the system measure the residual chlorine existing the water after the chlorine has been in the water for a specified period of time (lag time).

• In any chlorination system, the total lag time is calculated as the elapsed time after the water is injected with chlorine up to the point when the water enters the sample flow cell of the FX-1000p.

The FX-1000p Amperometric Chlorine Analyzer can measure only the residual chlorine actually reaching its sample flow cell. The sampling point should always be close to the sample flow cell so that the residual chlorine in the water sample at that point is essentially the same as that in the water going through the flow cell. This is most important for installations where the lag time is relatively short.

Sample Line:

When installing the sample line into the process pipe use brass or plastic fittings as they are less likely to corrode than iron fittings. A sample valve upstream of the sample flow cell inlet tubing is required. We suggest using a metering ball valve, needle valve or globe valve. Ensure that the water sample line is capable of delivering a continuous flow between 150 and 1000 ml per minute to the sample valve at approximately 15 psi. If pressure exceeds 50 psi, use an auxiliary water pressure reducing valve. If necessary, increase the flow to the sample cell to reduce the water sample transport time.
Plumbing Guidelines
FX-1000p Sampling Specifications
Sample Temperature Range 32-120° (0-49°C)
Sample Flow Rate 150-1000 ml/min (200 ml/min recommended
Sample Supply Where sample flow is interrupted, provisions must be made to keep the electrodes wet.
Sample pH Range 3.0-10.0 pH
Sample Alkalinity Range 0.05-350 ppm total (mg/l)
Sample Turbidity Limit Less than 250 NTU
Sample Inlet Line 3/8" od x 1/4" id clear flexible PVC hose, 3 ft long
Drain Lines Two 3/4" od x 5/8" id, clear flexible PVC Hoses, 3 ft. long each
Typical Sample Connection Typical Sample Connection
Clean Water Conditions
For drinking water and other clean water applications, here are suggested way's to plumb your chlorine analyzer. Click on Image to open PDF File
Clean Water Clean Water Applications
 
Dirty Water Conditions
For wastewater and other dirty water applications, here are suggested way's to plumb your chlorine analyzer. The use of a flushing wye strainer maintains a clean analyzer. Click on Image to open PDF File.
Dirty Water Dirty Water Applications
 
Reservoirs
Here is a suggested way to plumb a reservoir application (closed body of water). Some reservoir applications are wet wells, swimming pools, large body of water, etc. Click image to open PDF File.
FX-1000p Plumbing a Reservoir FX-1000p Reservoir Application
 
Non-Continuous Sample Operations
Applications were the sample to the FX-1000p in non-continuous, meaning no flow conditions from time to time. Example, industrial processes (night time plant shuts down, well system, etc. Click image to open PDF File.
Plumbing for Non-Continuous Sample Operatins Non-Continuous Sampe Operation
 
Carbon Filters (use for zeroing analyzer)
Installing a carbon: The FX-1000p requires a unchlorinated water sample to zero the analyzer. If turning off the chlorination system is not possible to obtain an unchlorinated water sample, a carbon filter should be used. Click Image to open PDF file.
Calibration Installing a Carbon Filter
 
Dilution Panel to measure chlorine residuals from 100 to 50,000 ppm and higher
Dilution Panel: Believe it or not, by using this panel you can measure chlorine residuals as high as 50,000 ppm (5%) or higher. All mechanical device, requires no adjustment when operating. Click image to open PDF File
Dilution Panel Connection Dilution Panel
Measure Bleach
 
Foxcroft
FX-1000p Chlorine Analzyer
Plumbing
Protects the Enviroment
FX-1000p Chlorine Analyzer
EPA Approved
Foxcroft Equipment and Service Company, Incorporated
2101 Creek Road - Glenmoore, PA 19343 - USA
1.800.874.0590 - 1.610.942.2888 - FAX 1.610.942.2769
Email: sales@foxcroft.com

All Rights Reserved - All material contained in this Web Site is copyrighted - No material or ideas contained within this Web Site shall be used or copied without written consent from Foxcroft.
©2009 RWI3rd