Data Logging Data Logging (optional)

Create digital files by using the FX-USB data Logger.
Data Logging FX-Data Logger

This data logger measures and stores up to 32,000 readings over a measurement range. The user can easily set up the logging rate, and download the stored data by plugging the module straight into a PC's USB port and running the purpose designed software under Windows 98, 2000, XP or Vista. The data can then be graphed, printed and exported to other applications. The data logger independently powered by a long-life lithium battery. Correct functioning of the unit is indicated by a flashing red and green LED.
Data Logging Data Logger Features

• Stores 32,000 Readings
• USB Interface
• Logging Rate (1s - 12hrs)
• Replaceable Lithium Battery
Data Logger
Data Logger No Charts Required
  Reliability and Longevity

Any device that uses sensitive moving parts can fail at any time. To prevent errors and downtime, these moving parts must be carefully maintained. Depending on the type of chart recorder, maintenance can be labor intensive and time consuming. Example changing and annotating paper chart weekly or daily, general cleaning and pen changes and recorder calibrations.
Data Logger Specifications
Data Logging Data Logger Specifications
  Min. Typ. Max. Unit
Internal Resolution   ±0.05   ppm
Accuracy (overall error)   ±1   % ±1 Count
Logging rate every 1s   every 12hr  
Operating temperature range -35 (-31)   +80 (176) °C (°F)
1/2AA 3.6 Lithium Battery Life* 1     Year
Data Logger Setup and Downloads
Data Logging Data Logger Setup and Downloads

Control Software
Install and use control software runs under Window 98, 2000, XP and Vista. It allows the user to set up and download any FX-Data Logger.
  Data Logger Set-ups

• Logger Name
• Logging Rate (1s, 10s, 1m, 5m, 30m, 1hr, 12hr)
• High and Low Alarms
• Start Date and Start Time
Data Logger Setup
Sample a Download
Sample Information File Downloads

Download via USB port
Print File (Graphed)
Print TXT Files

The data can be graphed, printed and exported to other applications.
Data Sample
Data Logger Highlights
Data Logger Data Logger Highlights
Data Logger Highlights
Data Logger Status LED's
Data Logger Status Indications
Data Logging Data Logger Status LED's

The LED's on the FX-Data Logger will flash in one of the following ways, assuming alarm latching is turned off.
Green LED Green single flash, every 30 seconds Logger primed and ready to start.
Green LED Green single flash, every 10 seconds Logging in progress, last stored value OK
Red LED Red single flash, every 10 seconds Logging in progress, the last stored reading is equal to or exceeds the low alarm
Red LED Red double flash every 10 seconds Logging in progress, the last stored reading is equal to or exceeds the high alarm level
Green LED Green single flash, every 20 seconds Low battery, logging in progress, the last stored value OK
Red LED Red single flash, every 20 seconds Low battery, logging in progress, the last stored value is equal to or exceed the low alarm level
Red LED Red double flash, every 20 seconds Low battery, logging in progress, the last stored value is equal to or exceeds the high alarm level
Green LED Green double flash, every 20 seconds Logger is full, last stored value OK
Red and Green LED Green LED Red/Green single flash, every 20 seconds alarm latching turned on Logger is full, last stored value is equal to or exceeds the low or high alarm levels
  No LED's flash LED's disabled during configuration to save battery power and increase logging duration or battery dead.
EPA Approved
 
 
Foxcroft
FX-1000p Chlorine Analzyer
Protects the Enviroment
FX-1000p Chlorine Analyzer
Data Logging (optional)
Foxcroft Equipment and Service Company, Incorporated
2101 Creek Road - Glenmoore, PA 19343 - USA
1.800.874.0590 - 1.610.942.2888 - FAX 1.610.942.2769
Email: sales@foxcroft.com

All Rights Reserved - All material contained in this Web Site is copyrighted - No material or ideas contained within this Web Site shall be used or copied without written consent from Foxcroft.
©2009 RWI3rd